Abstract
A cyclone impactor has been modified to include an ionizing radiation source and a SAW device in place of the usual filter. The SAW has been incorporated in an oscillator circuit and, with a chemical treatment of the collection plate, the real time response to particulate matter is demonstrated.
| Original language | English |
|---|---|
| Pages (from-to) | 231-235 |
| Number of pages | 5 |
| Journal | Nondestructive Testing and Evaluation |
| Volume | 20 |
| Issue number | 4 |
| DOIs | |
| Publication status | Published - 1 Dec 2005 |
Keywords / Materials (for Non-textual outputs)
- surface acoustic wave
- SAW
- sensor
- particulate
- electrostatic
- precipitator
Fingerprint