Projects per year
Abstract / Description of output
The volume ratio in the total solid particle mixture
is an important parameter indicating the characteristics of
partculate mixtures. Therefore, a simple measurement method is
desirable. In this paper, the normalized permittivity of two groups
of particle mixtures are tested using Electrical Capacitance
Tomography (ECT) with the series and parallel models. The
experimental results show that normalized permittivity changes
obtained from the series ECT model have a very strong linear
relationship with the volume ratio of higher permittivity materials
in the mixture. The Maxwell Garnett Formula (MGF) can predict
the normalized permittivity only after the permittivity of each type
of particle is known. The comparison between two methods
suggests that ECT with series model is a better way for monitoring
the volume ratio in the mixtures with two types of solid particles.
is an important parameter indicating the characteristics of
partculate mixtures. Therefore, a simple measurement method is
desirable. In this paper, the normalized permittivity of two groups
of particle mixtures are tested using Electrical Capacitance
Tomography (ECT) with the series and parallel models. The
experimental results show that normalized permittivity changes
obtained from the series ECT model have a very strong linear
relationship with the volume ratio of higher permittivity materials
in the mixture. The Maxwell Garnett Formula (MGF) can predict
the normalized permittivity only after the permittivity of each type
of particle is known. The comparison between two methods
suggests that ECT with series model is a better way for monitoring
the volume ratio in the mixtures with two types of solid particles.
Original language | English |
---|---|
Journal | IEEE Access |
Early online date | 11 Aug 2017 |
DOIs | |
Publication status | E-pub ahead of print - 11 Aug 2017 |
Keywords / Materials (for Non-textual outputs)
- Electrical Capacitance Tomography (ECT)
- Volume ratio
- Maxwell Garnett Formula
- Normalized permittivity
Fingerprint
Dive into the research topics of 'Correlation of Volume Ratio and Normalized Permittivity in Particle Mixture'. Together they form a unique fingerprint.Projects
- 1 Finished
Research output
- 1 Doctoral Thesis
-
Advanced digital electrical impedance tomography system for biomedical imaging
Yang, Y., Jul 2018, 167 p.Research output: Thesis › Doctoral Thesis
Open Access