Diagnostic accuracy and limitations of post-mortem MRI for neurological abnormalities in fetuses and children

Magnetic Resonance Imaging Autopsy Study (MaRIAS) Collaborative Group

Research output: Contribution to journalArticlepeer-review

Abstract / Description of output

AIM: To compare the diagnostic accuracy of non-invasive cerebral post-mortem magnetic resonance imaging (PMMRI) specifically for cerebral and neurological abnormalities in a series of fetuses and children, compared to conventional autopsy.

MATERIALS AND METHODS: Institutional ethics approval and parental consent was obtained. Pre-autopsy cerebral PMMRI was performed in a sequential prospective cohort (n = 400) of fetuses (n = 277; 185 ≤ 24 weeks and 92 > 24 weeks gestation) and children <16 years (n = 123) of age. PMMRI and conventional autopsy findings were reported blinded and independently of each other.

RESULTS: Cerebral PMMRI had sensitivities and specificities (95% confidence interval) of 88.4% (75.5 to 94.9), and 95.2% (92.1 to 97.1), respectively, for cerebral malformations; 100% (83.9 to 100), and 99.1% (97.2 to 99.7) for major intracranial bleeds; and 87.5% (80.1 to 92.4) and 74.1% (68 to 79.4) for overall brain pathology. Formal neuropathological examination was non-diagnostic due to maceration/autolysis in 43/277 (16%) fetuses; of these, cerebral PMMRI imaging provided clinically important information in 23 (53%). The sensitivity of PMMRI for detecting significant ante-mortem ischaemic injury was only 68% (48.4 to 82.8) overall.

CONCLUSIONS: PMMRI is an accurate investigational technique for identifying significant neuropathology in fetuses and children, and may provide important information even in cases where autolysis prevents formal neuropathological examination; however, PMMRI is less sensitive at detecting hypoxic-ischaemic brain injury, and may not detect rarer disorders not encountered in this study.

Original languageEnglish
Pages (from-to)872-80
Number of pages9
JournalClinical Radiology
Volume70
Issue number8
DOIs
Publication statusPublished - Aug 2015

Keywords / Materials (for Non-textual outputs)

  • Adolescent
  • Autopsy/methods
  • Brain/abnormalities
  • Brain Diseases/diagnosis
  • Child
  • Child, Preschool
  • Fetus/abnormalities
  • Humans
  • Hypoxia-Ischemia, Brain/diagnosis
  • Infant
  • Infant, Newborn
  • Intracranial Hemorrhages/diagnosis
  • Magnetic Resonance Imaging/methods
  • Prospective Studies
  • Sensitivity and Specificity

Fingerprint