Does trans-radial longitudinal compression influence myoelectric control?

Jennifer Olsen, Sarah Day, Sigrid Dupan, Kianoush Nazarpour, Matthew Dyson

Research output: Contribution to journalArticlepeer-review

Abstract

BACKGROUND: Existing trans-radial prosthetic socket designs are not optimised to facilitate reliable myoelectric control. Many socket designs pre-date the introduction of myoelectric devices. However, socket designs featuring improved biomechanical stability, notably longitudinal compression sockets, have emerged in more recent years. Neither the subsequent effects, if any, of stabilising the limb on myoelectric control nor in which arrangement to apply the compression have been reported.METHODOLOGY: Twelve able-bodied participants completed two tasks whilst wearing a longitudinal compression socket simulator in three different configurations: 1) compressed, where the compression strut was placed on top of the muscle of interest, 2) relief, where the compression struts were placed either side of the muscle being recorded and 3) uncompressed, with no external compression. The tasks were 1) a single-channel myoelectric target tracking exercise, followed by 2), a high-intensity grasping task. The wearers’ accuracy during the tracking task, the pressure at opposing sides of the simulator during contractions and the rate at which the limb fatigued were observed.FINDINGS: No significant difference between the tracking-task accuracy scores or rate of fatigue was observed for the different compression configurations. Pressure recordings from the compressed configuration showed that pressure was maintained at opposing sides of the simulator during muscle contractions.CONCLUSION: Longitudinal compression does not inhibit single-channel EMG control, nor improve fatigue performance. Longitudinal compression sockets have the potential to improve the reliability of multi-channel EMG control due to the maintenance of pressure during muscle contractions
Original languageEnglish
Number of pages12
JournalCanadian Prosthetics & Orthotics Journal
Volume5
Issue number2
DOIs
Publication statusPublished - 20 Jul 2022

Keywords / Materials (for Non-textual outputs)

  • upper limb prosthetics
  • trans-radial
  • myoelectric prosthetics
  • myoelectric signals
  • amputation
  • prosthetic
  • socket
  • compression
  • myoelectric
  • EMG
  • control
  • fatigue
  • compression release

Fingerprint

Dive into the research topics of 'Does trans-radial longitudinal compression influence myoelectric control?'. Together they form a unique fingerprint.

Cite this