Abstract
Objectives
Coronary artery calcium (CAC) scores derived from computed tomography (CT) scans are used for cardiovascular risk-stratification. Artificial intelligence (AI) can assist in CAC quantification and potentially reduce the time required for human analysis. This study aimed to develop and evaluate a fully automated model that identifies and quantifies CAC.
Methods
Fully convolutional neural networks for automated CAC scoring were developed and trained on 2439 cardiac CT scans and validated using 771 scans. The model was tested on an independent set of 1849 cardiac CT scans. Agatston CAC scores were further categorised into five risk categories (0, 1-10, 11-100, 101-400 and >400). Automated scores were compared to the manual reference standard (level 3 expert readers).
Results
Of 1849 scans used for model testing (mean age 55.7±10.5 years, 49% males), the automated model detected the presence of CAC in 867 (47%) scans compared with 815 (44%) by human readers (P=0.09). CAC scores from the model correlated very strongly with the manual score (Spearman’s r=0.90, 95% confidence interval [CI] 0.89-0.91, P<0.001 and intraclass correlation coefficient=0.98, 95% CI 0.98-0.99, P<0.001). The model classified 1646 (89%) into the same risk category as human observers. Bland–Altman analysis demonstrated little difference (1.69, 95% limits of agreement: -41.22, 44.60) and there was almost excellent agreement (Cohen’s κ=0.90, 95% CI 0.88-0.91, P<0.001). Model analysis time was 13.13.2 seconds/scan.
Conclusions
This artificial intelligence-based fully automated CAC scoring model shows high accuracy and low analysis times. Its potential to optimise clinical workflow efficiency and patient outcomes requires evaluation.
Coronary artery calcium (CAC) scores derived from computed tomography (CT) scans are used for cardiovascular risk-stratification. Artificial intelligence (AI) can assist in CAC quantification and potentially reduce the time required for human analysis. This study aimed to develop and evaluate a fully automated model that identifies and quantifies CAC.
Methods
Fully convolutional neural networks for automated CAC scoring were developed and trained on 2439 cardiac CT scans and validated using 771 scans. The model was tested on an independent set of 1849 cardiac CT scans. Agatston CAC scores were further categorised into five risk categories (0, 1-10, 11-100, 101-400 and >400). Automated scores were compared to the manual reference standard (level 3 expert readers).
Results
Of 1849 scans used for model testing (mean age 55.7±10.5 years, 49% males), the automated model detected the presence of CAC in 867 (47%) scans compared with 815 (44%) by human readers (P=0.09). CAC scores from the model correlated very strongly with the manual score (Spearman’s r=0.90, 95% confidence interval [CI] 0.89-0.91, P<0.001 and intraclass correlation coefficient=0.98, 95% CI 0.98-0.99, P<0.001). The model classified 1646 (89%) into the same risk category as human observers. Bland–Altman analysis demonstrated little difference (1.69, 95% limits of agreement: -41.22, 44.60) and there was almost excellent agreement (Cohen’s κ=0.90, 95% CI 0.88-0.91, P<0.001). Model analysis time was 13.13.2 seconds/scan.
Conclusions
This artificial intelligence-based fully automated CAC scoring model shows high accuracy and low analysis times. Its potential to optimise clinical workflow efficiency and patient outcomes requires evaluation.
| Original language | English |
|---|---|
| Journal | European Radiology |
| DOIs | |
| Publication status | Published - 20 Aug 2022 |
Keywords / Materials (for Non-textual outputs)
- Artificial intelligence
- Cardiovascular diseases
- Coronary artery disease
- Neural networks
- Tomography
- X-ray computed
Fingerprint
Dive into the research topics of 'Evaluation of an Artificial Intelligence Coronary Artery Calcium Scoring Model from Computed Tomography'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver