Skip to main navigation Skip to search Skip to main content

Fire behaviour of a timber composite with GFRP reinforcement compared to unreinforced laminated timber

Research output: Contribution to conference › Paper › peer-review

Abstract

Engineered timber is becoming increasingly popular due to many advantages such as sustainability andease of installation. However, its fire performance is largely hindering implementation of timberstructures. Combination of timber with composites such as glass fibre-reinforced polymers (GFRP) canimprove the fire performance of timber structures. Glass fibres are inorganic, thus not oxidising whenexposed to fire conditions. This paper presents a comparative study between the fire behaviour of atimber-GFRP composite laminate versus a pure timber laminate. The composite samples consisted ofsix timber veneers in between seven layers of GFRP. Tests were conducted using a Cone Calorimeterwith an external heat flux of 35 kW/m2. Heat release rate (HRR), mass and in-depth temperature weremeasured to investigate fire performance improvement.Results showed that samples without GFRP burned until under 10 % of their initial mass was left,whereas samples with GFRP reached flame self-extinction at 50 % of their initial mass. After an initialshort peak, the HRR of composite samples quickly declined to values below 100 kW/m2, while puretimber samples experienced delamination and a fluctuating HRR around 300 kW/m2 until burnout.GFRP-samples showed a significant heat gradient through the thickness with rear surface temperaturesof below 200 °C, while samples without GFRP reached 700 °C. This work shows that the glass fibresact as a barrier hindering oxidation of the charred timber, thus better insulating the deeper layers.Furthermore, if stitched adequately, the glass fibres can mechanically prevent the charred timber layersfrom delaminating.

Original languageEnglish
Pages155-160
Number of pages6
Publication statusPublished - 2019
Event9th Biennial Conference on Advanced Composites in Construction 2019, ACIC 2019 - Birmingham, United Kingdom
Duration: 3 Sept 2019 → 5 Sept 2019

Conference

Conference9th Biennial Conference on Advanced Composites in Construction 2019, ACIC 2019
Country/TerritoryUnited Kingdom
CityBirmingham
Period3/09/19 → 5/09/19

Keywords / Materials (for Non-textual outputs)

  • Charring rate
  • Engineered timber
  • Fire performance
  • Heat release rate
  • Ignition
  • In-depth temperature
  • Mass loss

Fingerprint

Dive into the research topics of 'Fire behaviour of a timber composite with GFRP reinforcement compared to unreinforced laminated timber'. Together they form a unique fingerprint.

Cite this