TY - JOUR
T1 - Iron Deposition following Chronic Myocardial Infarction as a Substrate for Cardiac Electrical Anomalies
T2 - Initial Findings in a Canine Model
AU - Cokic, Ivan
AU - Kali, Avinash
AU - Wang, Xunzhang
AU - Yang, Hsin Jung
AU - Tang, Richard L Q
AU - Thajudeen, Anees
AU - Shehata, Michael
AU - Amorn, Allen M.
AU - Liu, Enzhao
AU - Stewart, Brian
AU - Bennett, Nathan
AU - Harlev, Doron
AU - Tsaftaris, Sotirios A.
AU - Jackman, Warren M.
AU - Chugh, Sumeet S.
AU - Dharmakumar, Rohan
PY - 2013/9/16
Y1 - 2013/9/16
N2 - Purpose:Iron deposition has been shown to occur following myocardial infarction (MI). We investigated whether such focal iron deposition within chronic MI lead to electrical anomalies.Methods:Two groups of dogs (ex-vivo (n = 12) and in-vivo (n = 10)) were studied at 16 weeks post MI. Hearts of animals from ex-vivo group were explanted and sectioned into infarcted and non-infarcted segments. Impedance spectroscopy was used to derive electrical permittivity (ε̄) and conductivity (σ̄). Mass spectrometry was used to classify and characterize tissue sections with (IRON+) and without (IRON-) iron. Animals from in-vivo group underwent cardiac magnetic resonance imaging (CMR) for estimation of scar volume (late-gadolinium enhancement, LGE) and iron deposition (T2*) relative to left-ventricular volume. 24-hour electrocardiogram recordings were obtained and used to examine Heart Rate (HR), QT interval (QT), QT corrected for HR (QTc) and QTc dispersion (QTcd). In a fraction of these animals (n = 5), ultra-high resolution electroanatomical mapping (EAM) was performed, co-registered with LGE and T2* CMR and were used to characterize the spatial locations of isolated late potentials (ILPs).Results:Compared to IRON- sections, IRON+ sections had higherε̄, but no difference inσ̄. A linear relationship was found between iron content and ε̄ (p<0.001), but not σ̄ (p = 0.34). Among two groups of animals (Iron (<1.5%) and Iron (>1.5%)) with similar scar volumes (7.28%±1.02% (Iron (<1.5%)) vs 8.35%±2.98% (Iron (>1.5%)), p = 0.51) but markedly different iron volumes (1.12%±0.64% (Iron (<1.5%)) vs 2.47%±0.64% (Iron (>1.5%)), p = 0.02), QT and QTc were elevated and QTcd was decreased in the group with the higher iron volume during the day, night and 24-hour period (p<0.05). EAMs co-registered with CMR images showed a greater tendency for ILPs to emerge from scar regions with iron versus without iron.Conclusion:The electrical behavior of infarcted hearts with iron appears to be different from those without iron. Iron within infarcted zones may evolve as an arrhythmogenic substrate in the post MI period.
AB - Purpose:Iron deposition has been shown to occur following myocardial infarction (MI). We investigated whether such focal iron deposition within chronic MI lead to electrical anomalies.Methods:Two groups of dogs (ex-vivo (n = 12) and in-vivo (n = 10)) were studied at 16 weeks post MI. Hearts of animals from ex-vivo group were explanted and sectioned into infarcted and non-infarcted segments. Impedance spectroscopy was used to derive electrical permittivity (ε̄) and conductivity (σ̄). Mass spectrometry was used to classify and characterize tissue sections with (IRON+) and without (IRON-) iron. Animals from in-vivo group underwent cardiac magnetic resonance imaging (CMR) for estimation of scar volume (late-gadolinium enhancement, LGE) and iron deposition (T2*) relative to left-ventricular volume. 24-hour electrocardiogram recordings were obtained and used to examine Heart Rate (HR), QT interval (QT), QT corrected for HR (QTc) and QTc dispersion (QTcd). In a fraction of these animals (n = 5), ultra-high resolution electroanatomical mapping (EAM) was performed, co-registered with LGE and T2* CMR and were used to characterize the spatial locations of isolated late potentials (ILPs).Results:Compared to IRON- sections, IRON+ sections had higherε̄, but no difference inσ̄. A linear relationship was found between iron content and ε̄ (p<0.001), but not σ̄ (p = 0.34). Among two groups of animals (Iron (<1.5%) and Iron (>1.5%)) with similar scar volumes (7.28%±1.02% (Iron (<1.5%)) vs 8.35%±2.98% (Iron (>1.5%)), p = 0.51) but markedly different iron volumes (1.12%±0.64% (Iron (<1.5%)) vs 2.47%±0.64% (Iron (>1.5%)), p = 0.02), QT and QTc were elevated and QTcd was decreased in the group with the higher iron volume during the day, night and 24-hour period (p<0.05). EAMs co-registered with CMR images showed a greater tendency for ILPs to emerge from scar regions with iron versus without iron.Conclusion:The electrical behavior of infarcted hearts with iron appears to be different from those without iron. Iron within infarcted zones may evolve as an arrhythmogenic substrate in the post MI period.
UR - http://www.scopus.com/inward/record.url?scp=84884194786&partnerID=8YFLogxK
U2 - 10.1371/journal.pone.0073193
DO - 10.1371/journal.pone.0073193
M3 - Article
C2 - 24066038
AN - SCOPUS:84884194786
SN - 1932-6203
VL - 8
JO - PLoS ONE
JF - PLoS ONE
IS - 9
M1 - e73193
ER -