Measuring Oxygenation in Newborn Infants with Targeted Oxygen Ranges (MONITOR): a randomised crossover pilot study

Fraser G Christie*, Rod Kelly, James P Boardman, Ben Stenson

*Corresponding author for this work

Research output: Contribution to journalArticlepeer-review

Abstract / Description of output

OBJECTIVE: The Neonatal Oxygenation Prospective Meta-analysis (NeOProM) Collaboration showed that high (91-95%) versus low (85-89%) SpO2 targets reduced mortality. Trials of higher targets are needed to determine whether any more survival advantage may be gained. This pilot study explored the achieved oxygenation patterns observed when targeting SpO2 92-97% to facilitate the design of future trials. DESIGN: Single-centre prospective randomised crossover pilot study. Manual FiO2 adjustment. Study time 12 hours per infant. 6 hours targeting SpO2 90-95% and 6 hours targeting SpO2 92-97%. PATIENTS: Twenty preterm infants born <29 weeks' gestation, greater than 48 hours old, receiving supplemental oxygen. OUTCOMES: Primary outcome was percentage time with SpO2 above 97% and below 90%. Pre-defined secondary outcomes included percentage time spent within, above or below transcutaneous PO2 (TcPO2) 6.7-10.7 kPa (50-80 mm Hg). Comparisons were made using paired-samples t-test (2-tailed). RESULTS: With SpO2 target 92-97% versus 90-95%, the mean (IQR) percentage time above SpO2 97% was 11.3% (2.7-20.9) versus 7.8% (1.7-13.9), p=0.02. Percentage time with SpO2 <90% was 13.1% (6.7-19.1) versus 17.9% (11.1-22.4), p=0.003. Percentage time with SpO2 <80% was 1% (0.1-1.4) versus 1.6% (0.4-2.6), p=0.119. Percentage time with TcPO2 <6.7 kPa (50 mm Hg) was 49.6% (30.2-66.0) versus 55% (34.3-73.5), p=0.63. Percentage time above TcPO2 10.7 kPa (80 mm Hg) was 1.4% (0-1.4) versus 1.8% (0-0), p=0.746. CONCLUSIONS: Targeting SpO2 92-97% produced a right shift in SpO2 and TcPO2 distribution, with reduced time at SpO2 <90% and increased time at SpO2 >97%, without increasing time with TcPO2 >10.7 kPa (80 mm Hg). Clinical trials targeting this higher SpO2 range could be conducted without significant hyperoxic exposure. TRIAL REGISTRATION NUMBER: NCT03360292.

Original languageEnglish
Pages (from-to)638-642
JournalArchives of Disease in Childhood
Volume108
Issue number6
Early online date4 May 2023
DOIs
Publication statusPublished - 1 Nov 2023

Keywords / Materials (for Non-textual outputs)

  • intensive care units, neonatal
  • neonatology

Fingerprint

Dive into the research topics of 'Measuring Oxygenation in Newborn Infants with Targeted Oxygen Ranges (MONITOR): a randomised crossover pilot study'. Together they form a unique fingerprint.

Cite this