TY - JOUR
T1 - Peppermint protocol: first results for gas chromatography-ion mobility spectrometry
AU - Ruszkiewicz, Dorota M
AU - Myers, Renelle
AU - Henderson, Ben
AU - Yusof, Hazim
AU - Meister, Austin
AU - Moreno, Sergi
AU - Eddleston, Michael
AU - Darnley, Kareen
AU - Nailon, William H
AU - Mclaren, Duncan
AU - Lao, Yvonne E
AU - Hovda, Knut Erik
AU - Lam, Stephen
AU - Cristescu, Simona M
AU - Thomas, C. L. Paul
AU - Peppermint Consortium
N1 - Funding Information:
We acknowledge gratefully European Union Horizon 2020 funding to Edinburgh and Oslo (TOXI-triage project H2020 funded project 653409).
Publisher Copyright:
© 2022 The Author(s). Published by IOP Publishing Ltd.
PY - 2022/5/26
Y1 - 2022/5/26
N2 - The Peppermint Initiative seeks to inform the standardisation of breath analysis methods. Five Peppermint Experiments with gas chromatography-ion mobility spectrometry (GC-IMS), operating in the positive mode with a tritium 3H 5.68 keV, 370 MBq ionisation source, were undertaken to provide benchmark Peppermint Washout data for this technique, to support its use in breath-testing, analysis, and research. Headspace analysis of a peppermint-oil capsule by GC-IMS with on-column injection (0.5 cm3) identified 12 IMS responsive compounds, of which the four most abundant were: eucalyptol; β-pinene; α-pinene; and limonene. Elevated concentrations of these four compounds were identified in exhaled-breath following ingestion of a peppermint-oil capsule. An unidentified compound attributed as a volatile catabolite of peppermint-oil was also observed. The most intense exhaled peppermint-oil component was eucalyptol, which was selected as a peppermint marker for benchmarking GC-IMS. Twenty-five washout experiments monitored levels of exhaled eucalyptol, by GC-IMS with on-column injection (0.5 cm3), at t = 0 min, and then at t + 60, t + 90, t + 165, t + 285 and t + 360 min from ingestion of a peppermint capsule resulting in 148 peppermint breath analyses. Additionally, the Peppermint Washout data was used to evaluate clinical deployments with a further five washout tests run in clinical settings generating an additional 35 breath samples. Regression analysis yielded an average extrapolated time taken for exhaled eucalyptol levels to return to baseline values to be 429 ± 62 min (±95% confidence-interval). The benchmark value was assigned to the lower 95% confidence-interval, 367 min. Further evaluation of the data indicated that the maximum number of volatile organic compounds discernible from a 0.5 cm3 breath sample was 69, while the use of an in-line biofilter appeared to reduce this to 34.
AB - The Peppermint Initiative seeks to inform the standardisation of breath analysis methods. Five Peppermint Experiments with gas chromatography-ion mobility spectrometry (GC-IMS), operating in the positive mode with a tritium 3H 5.68 keV, 370 MBq ionisation source, were undertaken to provide benchmark Peppermint Washout data for this technique, to support its use in breath-testing, analysis, and research. Headspace analysis of a peppermint-oil capsule by GC-IMS with on-column injection (0.5 cm3) identified 12 IMS responsive compounds, of which the four most abundant were: eucalyptol; β-pinene; α-pinene; and limonene. Elevated concentrations of these four compounds were identified in exhaled-breath following ingestion of a peppermint-oil capsule. An unidentified compound attributed as a volatile catabolite of peppermint-oil was also observed. The most intense exhaled peppermint-oil component was eucalyptol, which was selected as a peppermint marker for benchmarking GC-IMS. Twenty-five washout experiments monitored levels of exhaled eucalyptol, by GC-IMS with on-column injection (0.5 cm3), at t = 0 min, and then at t + 60, t + 90, t + 165, t + 285 and t + 360 min from ingestion of a peppermint capsule resulting in 148 peppermint breath analyses. Additionally, the Peppermint Washout data was used to evaluate clinical deployments with a further five washout tests run in clinical settings generating an additional 35 breath samples. Regression analysis yielded an average extrapolated time taken for exhaled eucalyptol levels to return to baseline values to be 429 ± 62 min (±95% confidence-interval). The benchmark value was assigned to the lower 95% confidence-interval, 367 min. Further evaluation of the data indicated that the maximum number of volatile organic compounds discernible from a 0.5 cm3 breath sample was 69, while the use of an in-line biofilter appeared to reduce this to 34.
U2 - 10.1088/1752-7163/ac6ca0
DO - 10.1088/1752-7163/ac6ca0
M3 - Article
SN - 1752-7155
VL - 16
JO - Journal of Breath Research
JF - Journal of Breath Research
IS - 3
M1 - 036004
ER -