Radio Frequency Based Vascular Dementia Sensing and Imaging System Targeting Smart Glasses

Research output: Contribution to journalArticlepeer-review

Abstract

Vascular dementia is the second most prevalent type of dementia among the elderly population and is one of the leading causes of mortality. Ischemic stroke and brain atrophy are the predominant pathologies associated with vascular dementia. Early detection and regular monitoring are crucial to prevent the advancement of vascular dementia. Conventional medical imaging is expensive, requires extensive medical supervision and is not easily accessible. This research presents a novel concept of low-cost and non-invasive smart glasses, equipped with miniaturized octagonal monopole-patch antenna (OMPA) sensors and a crescent array sensor for vascular dementia detection. This Radio Frequency (RF) enabled portable system is capable of accurately identifying and imaging brain infarction, atrophy and stroke in their early stages. The fabricated device is experimentally verified using multiple artificial stroke and atrophy targets inside a realistic brain phantom. The backscattered RF data is iteratively processed using customized imaging algorithms to achieve improved image quality, noise suppression, and contrast resolution with reduced image artifacts and computational complexity. Based on the iterative refinement, the Double Stage Minimum Variance Delay Multiply and Sum (DS-MV-DMAS) algorithm is proposed for imaging stroke and brain atrophy. The quantitative results indicate that DS-MV-DMAS results in 43% lower level of side lobes and leads to 26%, 28% and 27% improvement in signal-to-noise ratio, full width at halfmaximum and contrast ratio, respectively, compared to other state-of-the-art imaging algorithms. The promising results demonstrate the feasibility of the prototype system as a cost-effective, portable and non-invasive alternative for the diagnosis and monitoring of vascular dementia.
Original languageEnglish
Pages (from-to)7310-7322
JournalIEEE Sensors Journal
Volume25
Issue number4
Early online date9 Jan 2025
DOIs
Publication statusE-pub ahead of print - 9 Jan 2025

Keywords / Materials (for Non-textual outputs)

  • Brain atrophy
  • Microwave Medical Imaging
  • Non-invasive sensors
  • Radio Frequency sensing
  • Stroke
  • Vascular Dementia
  • radio frequency (RF) sensing
  • vascular dementia
  • microwave medical imaging
  • stroke
  • noninvasive sensors

Fingerprint

Dive into the research topics of 'Radio Frequency Based Vascular Dementia Sensing and Imaging System Targeting Smart Glasses'. Together they form a unique fingerprint.

Cite this