Using a portable near-infrared spectroscopy device to estimate the second ventilatory threshold

V Rodrigo-Carranza, Fernando Gonzalez-Mohino, Tony Turner, Jose Maria Gonzalez Rave, Sergio Rofriguez-Barbero

Research output: Contribution to journalArticlepeer-review

Abstract / Description of output

A breakpoint in a portable near-infrared spectroscopy (NIRS) derived deoxygenated haemoglobin (deoxy[Hb]) signal during an incremental VO2max running test has been associated with the second ventilatory threshold (VT2) in healthy participants. Thus, the aim was to examine the association between this breakpoint (NIRS) and VT2 in well-trained runners. Gas exchange and NIRS data were collected during an incremental VO2max running test for 10 well-trained runners. The breakpoint calculated in oxygen saturation (StO2) and the VT2 were determined and compared in terms relative to %VO2max, absolute speed, VO2, and maximum heart rate (HRmax). There were no significant differences (p>0.05) between the breakpoint in StO2 and VT2 relative to %VO2max (87.00±6.14 and 88.28 ± 3.98 %), absolute speed (15.70±1.42 and 16.10±1.66 km·h−1), VO2 (53.71±15.17 and 54.66±15.57 ml·kg−1·min−1), and%HRmax (90.90±4.17 and 91.84±3.70%). There were large and significant correlations between instruments relative to%VO2max (r=0.68, p<0.05), absolute speed (r=0.86, p<0.001), VO2 (r=0.86, p<0.001), and %HRmax (r=0.69; p<0.05). A Bland and Altman analysis of agreement between instruments resulted in a mean difference of − 1.27±4.49%, −0.40±0.84 km·h−1,−0.90±3.07 ml·kg−1·min−1, and − 0.94±3.14 for %VO2max, absolute speed, VO2, and %HRmax, respectively. We conclude that a portable NIRS determination of the StO2 breakpoint is comparable with VT2 using gas exchange and therefore appropriate for use in determining exercise training above VT2 intensity. This is the first study to analyze the validity with the running mode using a NIRS portable device.
Original languageEnglish
Pages (from-to)905-910
JournalInternational Journal of Sports Medicine
Volume42
Issue number10
Early online date1 Feb 2021
DOIs
Publication statusPublished - 1 Sept 2021

Keywords / Materials (for Non-textual outputs)

  • intramuscular oxygenation
  • gas exchange threshold
  • incremental running test
  • athletes
  • exercise intensity

Fingerprint

Dive into the research topics of 'Using a portable near-infrared spectroscopy device to estimate the second ventilatory threshold'. Together they form a unique fingerprint.

Cite this