Edinburgh Research Explorer

Automated segmentation of multifocal basal ganglia T2*-weighted MRI hypointensities

Research output: Contribution to journalArticle

Related Edinburgh Organisations

Open Access permissions

Open

Documents

  • Download as Adobe PDF

    Rights statement: Available under a CC-BY license

    Final published version, 1 MB, PDF-document

    Licence: Creative Commons: Attribution (CC-BY)

http://www.sciencedirect.com/science/article/pii/S105381191400812X#
Original languageEnglish
Pages (from-to)332-346
Number of pages15
JournalNeuroImage
Volume105
Early online date14 Oct 2014
DOIs
Publication statusPublished - 15 Jan 2015

Abstract

Multifocal basal ganglia T2*-weighted (T2*w) hypointensities, which are believed to arise mainly from vascular mineralization, were recently proposed as a novel MRI biomarker for small vessel disease and ageing. These T2*w hypointensities are typically segmented semi-automatically, which is time consuming, associated with a high intra-rater variability and low inter-rater agreement. To address these limitations, we developed a fully automated, unsupervised segmentation method for basal ganglia T2*w hypointensities. This method requires conventional, co-registered T2*w and T1-weighted (T1w) volumes, as well as region-of-interest (ROI) masks for the basal ganglia and adjacent internal capsule generated automatically from T1w MRI. The basal ganglia T2*w hypointensities were then segmented with thresholds derived with an adaptive outlier detection method from respective bivariate T2*w/T1w intensity distributions in each ROI. Artefacts were reduced by filtering connected components in the initial masks based on their standardised T2*w intensity variance and appearance on T1w MRI. The segmentation method was validated using a custom-built phantom containing mineral deposit models, i.e. gel beads doped with 3 different contrast agents in 7 different concentrations, as well as with MRI data from 98 community-dwelling older subjects in their seventies with a wide range of basal ganglia T2*w hypointensities. The method produced basal ganglia T2*w hypointensity masks that were in substantial volumetric and spatial agreement with those generated by an experienced rater (Jaccard index = 0.62 ± 0.40). These promising results suggest that this method may have use in automatic segmentation of basal ganglia T2*w hypointensities in studies of small vessel disease and ageing.

    Research areas

  • Magnetic resonance imaging (MRI), Basal ganglia, Mineralization, Ageing, Focal T2*-weighted MRI hypointensities, Automated segmentation, Outlier detection, MAGNETIC-RESONANCE, BRAIN IRON, TRANSVERSE RELAXATION, IMAGES, ROBUST, AGE, BIRTH, MINERALIZATION, OPTIMIZATION, DEPOSITS

Download statistics

No data available

ID: 17135720